You are leaving your country page

Some features displayed on the USA website may not be available in your country.

Specs.

Hardware.

Dimensions
163 x 56 x 35 mm (6.4 x 2.2 x 1.4 in.)
Weight
309 grams (0.68 lbs)
Cable length
1.5 meters (4.92 feet)
Battery
2600 mAh Lithium Ion Battery
Battery life
≥2 continuous hours of scanning
Recharge time
5 hours (for full recharge)
Wireless charging
Qi-compatible
2D array, 9000 micro-machined sensors

Compatibility.

Compatible devices
Please see the list of compatible devices here.

Butterfly TeleGuidance™² is only compatible with a limited number of devices.
Please see the list here

Butterfly iQ+ Care is only compatible with a limited number of devices. Please see the list here

Caption Health is only compatible with a limited number of devices.
Please see the list here

Reimbursement.

Reimbursement guidelines for Butterfly iQ+
An overview of suggested reimbursement guidelines and relevant CPT codes for Butterfly iQ+.
Download

Cleaning.

How to clean Butterfly iQ+
1. After each use of the probe, use one of the recommended liquid saturated wipes (SuperSani-Cloth Germicidal Disposable Wipes by PDI, Inc., Super Sani-Cloth AF3 Disposable Wipes by PDI, Inc., or a lint-free cloth moistened with water) to remove ultrasound transmission gel from the probe.

2. Disconnect the probe from the mobile device.

3. Wipe the probe, strain relief, cable, and connector with one of the recommended liquid saturated wipes for one (1) minute and until visibly clean.

4. Change the wipes as necessary and repeat the above step until the probe is visibly clean.

5. To dry the probe, use a soft cloth to blot the lens dry. Do not wipe the lens. Dry the rest of the probe, cable, strain relief, and connector.

6. Visually inspect the probe in a well-lit area to ensure all surfaces are clean. If the probe is not clean, repeat the cleaning steps above.

7. Dispose of cleaning material in accordance with all applicable regulations.
Download the cleaning and disinfection guide here

Imaging.

Modes
M-mode, B-mode, Colour Doppler, Power Doppler, Pulsed Wave Doppler1
Min/max scan depth
1cm / 30cm
Measurements and annotations
Linear measurements (max of 4)
Ellipse measurement (max of 1)
Text labels (create your own or choose from 80+ preset-specific labels)
Tools
Biplane Imaging™³
Needle Viz™
OB Calculations
Midline marker
Auto Bladder Volume⁴
Manual Volume Calculation
Controls
Gain
TGC (near, mid, far)
Depth

Presets.

Abdomen
Read more +
Read more +

The Abdomen preset uses harmonic frequencies in a curvilinear format to support the clinical assessment of structures the size and morphology of abdominal organs, such as the liver and kidney, to a depth of 25cm. It is also used for abdominal procedures, such as paracentesis or ECMO lines in the IVC.

Abdomen Deep
Read more +

Abdomen Deep uses the fundamental low frequencies required to provide the depth of penetration necessary for abdominal assessments of up to 30cm. This curvilinear preset is typically reserved for technically challenging patients, such as high BMI or those with highly attenuating livers, as in hepatitis.

Aorta & Gallbladder
Read more +

Aorta/Gallbladder uses imaging parameters which allow high-contrast imaging for these specific abdominal structures. This is designed for optimal delineation of borders, and so is best applied in the investigations of AAA, CBD, gallbladder disease, cholelithiasis, and pericholecystic fluid—common investigations in primary care and the emergency room.

Bladder
Read more +

The Bladder preset has been optimised for the contrast and detail required for bladder assessment. The Field of View (FOV) is expanded to 120 degrees to enable broader visualisation of the bladder to a depth up to 20cm. This curvilinear preset includes the application of harmonic imaging for high resolution imaging. It provides the penetration necessary for visualisation of the entire bladder, and the contrast resolution required to demonstrate the bladder wall with confidence. This preset is best applied for the investigation of urinary retention, bladder wall health, urethral valve patency and prostate size.

Cardiac
Read more +

The Cardiac preset operates with a high-frame-rate phased array, and uses fundamental frequencies to allow reliable real-time echocardiographic interrogation of cardiac anatomy. This preset penetrates to 25cm, and is used actively by many bedside specialty clinicians in a diverse array of clinical environments such as the ED, ICU, Cardiology office and for peri-operative assessment in the PACU for global heart health assessment. It can also be used for thoracic procedures, such as pericardiocentesis.

Cardiac Deep
Read more +

The Cardiac Deep preset has an alternate optimisation developed to provide imaging flexibility in assessment of different patient types. It features a higher resonant frequency and a harmonic component to offer a different look. With its high frame rate, it offers reliable real-time echocardiographic interrogation up to 25cm.

Coherence Imaging
Read more +

Coherence Imaging, located in the Cardiac preset, enhances the image by removing unmodeled acoustic reverberation and aberration (typically known as “clutter”) and improving contrast resolution for support of binary decision-making.

FAST
Read more +

The FAST preset has been optimised for performance of the FAST (Focused Assessment with Sonography in Trauma) examination, which assists the clinician to identify free intraperitoneal or pericardial fluid in blunt trauma patients. It is a cornerstone of point-of-care ultrasound in both Emergency Medicine and EMS. The preset penetrates to 25cm, and is a combination of technical characteristics that provide high frame rate for cardiac imaging (typically the subxiphoid view) yet high detail for interrogation of the deep pelvis and abdomen.

Lung
Read more +

A popular preset to help triage and care expedition in the fight against COVID-19, the Lung preset has been optimised for demonstration of the pleural surface and lung sliding in the foreground, as well as A-line and B-lines throughout the 15cm field. Of note, the preset has been designed to anticipate these needs of the user, by transforming from a linear array to curvilinear array at 7cm within this preset in order to optimise both for near-field lung sliding dynamics and B-lines, as well as A-lines in the mid to deeper field.

MSK-Soft Tissue
Read more +

MSK-Soft Tissue is our highest-frequency preset. It has been developed with high dynamic range for optimised detail resolution of soft tissue structures, such as intramuscular assessment. It is commonly used by advanced users of MSK point-of-care ultrasound looking for detailed anatomical assessment. The preset penetrates from a minimum depth of 1cm to a maximum of 12cm. The user will notice the preset automatically translates from linear to trapezoidal format (4cm), and then to curvilinear (8cm) to support superficial trigger finger assessments through to deep inguinal hernia and hip-joint interrogation and needle guidance. It is also a popular preset applied by board-certified plastic surgeons in the investigation of symptomatic breast implant studies.

Musculoskeletal
Read more +

Musculoskeletal is a partner preset for MSK-Soft Tissue. It has been developed with a focus on contrast resolution to highlight crisp borders between structures, and needles with “pop”. It tends to be preferred by those users performing interventions, as well as for diagnostic procedures requiring crisp border detection such as in DDH, as well as rheumatology. The preset penetrates from a minimum depth of 1cm to a maximum of 12cm, and automatically translates from linear to trapezoidal format (4cm), and then to curvilinear (8cm). As a result, the Musculoskeletal preset can support inspection/injection of the peripheral joints as well as support the depth of penetration necessary for hip joint, and even epidurals.

Nerve
Read more +

The Nerve preset has been developed in collaboration with regional and peri-operative anaesthesiologists. It is a high-frequency linear imaging format optimised for interrogation of the peripheral nerves, to a depth of 5cm. It has been developed to show contrast between the nerve bundle, distinct from surrounding structures and yet maintain the detail resolution required to demonstrate the typical “honeycomb” appearance of individual nerve fascicles.

OB 1/GYN
Read more +

The OB 1/GYN preset is a dedicated curvilinear obstetric preset for in-utero assessment of pregnancy and gynaecological patients to a depth of 25cm. The preset has been optimised for first trimester pregnancy studies and is particularly popular in Labour & Delivery, obstetric, and resource-limited settings.

OB 2/3
Read more +

The OB 2/3 preset is a dedicated curvilinear obstetric preset for in-utero assessment of pregnancy and gynaecological patients to a depth of 25cm. The preset has been optimised for second and third trimester pregnancy studies and is particularly popular in Labour & Delivery, obstetric, and resource-limited settings.

Ophthalmic
Read more +

The Ophthalmic preset has been carefully developed with the appropriate MI operating scope for point-of-care ultrasound examinations of the eye. This typically involves looking at structural integrity of the orbit, foreign bodies as well as optic nerve sheath diameter (ONSD). It is a linear preset, depth range to 5cm.

Pediatric Abdomen
Read more +

The Paediatric Abdomen preset uses harmonic frequencies in a curvilinear format to support the clinical assessment of the size and morphology of abdominal organs, such as the liver and kidney. This preset uses a higher frequency and can penetrate as deep as 15cm, optimised for paediatric assessment.

Pediatric Cardiac
Read more +

The Paediatric Cardiac preset operates with a high-frame-rate phased array, and uses frequencies to allow reliable real-time echocardiographic interrogation of cardiac anatomy. This preset penetrates to 15cm and is optimised for pediatric patients, including higher frequencies than its adult-companion preset.

Pediatric Lung
Read more +

The Paediatric Lung preset has been optimised for demonstration of the pleural surface and lung sliding in the foreground, as well as A-line and B-lines throughout the 7cm field. It is a preset popular for the detection of pulmonary consolidation associated with paediatric pneumonia, and is one of the highest-used presets by our Global Health NGO partners.

Small Organ
Read more +

The Small Organ preset has been optimised for the investigation of small soft tissue structures such as the thyroid, parotid gland, lymph nodes and testes in a linear format to a depth of 6cm. It can be used for both the qualitative and quantitative assessment of organ size, morphology and vascularity. Examples of the latter include: assessment of testicular torsion as well as Hashimoto’s Thyroiditis.

Vascular: Access
Read more +

The Vascular: Access preset has been designed to meet the high-contrast, high-resolution demands of ultrasound-guided venipunctures and arterial access procedures, with a linear format. It optimises imaging from a minimum of 1cm through to 5cm, and has a low grey-scale appearance to “pop out” both the vasculature, as well as the needle/catheter path, and tip.

Vascular: Carotid
Read more +

The Vascular: Carotid preset has been designed to meet the high-contrast, high-resolution demands of assessment of the carotid arteries, for peripheral arterial disease. It has been designed to support the identification of plaque, hemodynamic disturbance and stroke screening. It optimises imaging to 6cm, to accommodate a range of patient types. The preset has been optimised with a relatively low grey-scale appearance to “pop out” intimal boundaries. A great video to help get you started can be found here.

Vascular: Deep Vein
Read more +

The Vascular: Deep Vein preset has been designed to meet the high-contrast, high-resolution demands of assessment of the peripheral deep veins. It has been designed to support the identification of thrombosis by supporting frame rates that accommodate the typical compression maneuvers, the contrast resolution to support the demonstration of the thrombus itself, as well as support to 8cm. The preset has been optimised with a relatively low grey-scale appearance to “pop out” intimal boundaries.

Cloud.

Storage
Unlimited
Data organization
Unlimited custom archives
User rights
Administrators, Regular Users (Unlimited)
Sharing
Anonymized image sharing (no user account required)

Security.

Data at rest
256-Bit AES
Data in transit
HTTPS TLS 1.2 Encryption
User security
Secure User Authentication, Passwords follow NIST Standards
Application deployment
Aptible Enclave - HITRUST, SOC II Certified

Hardware.

Dimensions
163 x 56 x 35 mm (6.4 x 2.2 x 1.4 in.)
Weight
309 grams (0.68 lbs)
Cable length
1.5 meters (4.92 feet)
Battery
2600 mAh Lithium Ion Battery
Battery life
≥2 continuous hours of scanning
Recharge time
5 hours (for full recharge)
Wireless charging
Qi-compatible
2D array, 9000 micro-machined sensors

Compatibility.

Compatible devices
Please see the list of compatible devices here.

Reimbursement.

Reimbursement guidelines for the Butterfly iQ
An overview of suggested reimbursement guidelines and relevant CPT codes for Butterfly iQ.
Download

Cleaning.

How to clean Butterfly iQ
1. After each use of the probe, use one of the recommended liquid saturated wipes (SuperSani-Cloth Germicidal Disposable Wipes by PDI, Inc., Super Sani-Cloth AF3 Disposable Wipes by PDI, Inc., or a lint-free cloth moistened with water) to remove ultrasound transmission gel from the probe.

2. Disconnect the probe from the mobile device.

3. Wipe the probe, strain relief, cable, and connector with one of the recommended liquid saturated wipes for one (1) minute and until visibly clean.

4. Change the wipes as necessary and repeat the above step until the probe is visibly clean.

5. To dry the probe, use a soft cloth to blot the lens dry. Do not wipe the lens. Dry the rest of the probe, cable, strain relief, and connector.

6. Visually inspect the probe in a well-lit area to ensure all surfaces are clean. If the probe is not clean, repeat the cleaning steps above.

7. Dispose of cleaning material in accordance with all applicable regulations.
Download the cleaning and disinfection guide here

Imaging.

Modes
M-mode, B-mode, Colour Doppler, Power Doppler, Pulsed Wave Doppler¹
Min/max scan depth
1cm / 30cm
Measurements and annotations
Linear measurements (max of 4)
Ellipse measurement (max of 1)
Text labels (create your own or choose from 80+ preset-specific labels)
Tools
Biplane Imaging™³
Needle Viz™
OB Calculations
Midline marker
Auto Bladder Volume⁴
Manual Volume Calculation
Controls
Gain
TGC (near, mid, far)
Depth

Presets.

Abdomen
Read more +
Read more +

The Abdomen preset uses harmonic frequencies in a curvilinear format to support the clinical assessment of structures the size and morphology of abdominal organs, such as the liver and kidney, to a depth of 25cm. It is also used for abdominal procedures, such as paracentesis or ECMO lines in the IVC.

Abdomen Deep
Read more +

Abdomen Deep uses the fundamental low frequencies required to provide the depth of penetration necessary for abdominal assessments of up to 30cm. This curvilinear preset is typically reserved for technically challenging patients, such as high BMI or those with highly attenuating livers, as in hepatitis.

Aorta & Gallbladder
Read more +

Aorta/Gallbladder uses imaging parameters which allow high-contrast imaging for these specific abdominal structures. This is designed for optimal delineation of borders, and so is best applied in the investigations of AAA, CBD, gallbladder disease, cholelithiasis, and pericholecystic fluid—common investigations in primary care and the emergency room.

Bladder
Read more +

The Bladder preset has been optimised for the contrast and detail required for bladder assessment. The Field of View (FOV) is expanded to 120 degrees to enable broader visualisation of the bladder to a depth up to 20cm. This curvilinear preset includes the application of harmonic imaging for high resolution imaging. It provides the penetration necessary for visualisation of the entire bladder, and the contrast resolution required to demonstrate the bladder wall with confidence. This preset is best applied for the investigation of urinary retention, bladder wall health, urethral valve patency and prostate size.

Cardiac
Read more +

The Cardiac preset operates with a high-frame-rate phased array, and uses fundamental frequencies to allow reliable real-time echocardiographic interrogation of cardiac anatomy. This preset penetrates to 25cm, and is used actively by many bedside specialty clinicians in a diverse array of clinical environments such as the ED, ICU, Cardiology office and for peri-operative assessment in the PACU for global heart health assessment. It can also be used for thoracic procedures, such as pericardiocentesis.

Cardiac Deep
Read more +

The Cardiac Deep preset has an alternate optimisation developed to provide imaging flexibility in assessment of different patient types. It features a higher resonant frequency and a harmonic component to offer a different look. With its high frame rate, it offers reliable real-time echocardiographic interrogation up to 25cm.

Coherence Imaging
Read more +

Coherence Imaging, located in the Cardiac preset, enhances the image by removing unmodeled acoustic reverberation and aberration (typically known as “clutter”) and improving contrast resolution for support of binary decision-making.

FAST
Read more +

The FAST preset has been optimised for performance of the FAST (Focused Assessment with Sonography in Trauma) examination, which assists the clinician to identify free intraperitoneal or pericardial fluid in blunt trauma patients. It is a cornerstone of point-of-care ultrasound in both Emergency Medicine and EMS. The preset penetrates to 25cm, and is a combination of technical characteristics that provide high frame rate for cardiac imaging (typically the subxiphoid view) yet high detail for interrogation of the deep pelvis and abdomen.

Lung
Read more +

A popular preset to help triage and care expedition in the fight against COVID-19, the Lung preset has been optimised for demonstration of the pleural surface and lung sliding in the foreground, as well as A-line and B-lines throughout the 15cm field. Of note, the preset has been designed to anticipate these needs of the user, by transforming from a linear array to curvilinear array at 7cm within this preset in order to optimise both for near-field lung sliding dynamics and B-lines, as well as A-lines in the mid to deeper field.

MSK-Soft Tissue
Read more +

MSK-Soft Tissue is our highest-frequency preset. It has been developed with high dynamic range for optimised detail resolution of soft tissue structures, such as intramuscular assessment. It is commonly used by advanced users of MSK point-of-care ultrasound looking for detailed anatomical assessment. The preset penetrates from a minimum depth of 1cm to a maximum of 12cm. The user will notice the preset automatically translates from linear to trapezoidal format (4cm), and then to curvilinear (8cm) to support superficial trigger finger assessments through to deep inguinal hernia and hip-joint interrogation and needle guidance. It is also a popular preset applied by board-certified plastic surgeons in the investigation of symptomatic breast implant studies.

Musculoskeletal
Read more +

Musculoskeletal is a partner preset for MSK-Soft Tissue. It has been developed with a focus on contrast resolution to highlight crisp borders between structures, and needles with “pop”. It tends to be preferred by those users performing interventions, as well as for diagnostic procedures requiring crisp border detection such as in DDH, as well as rheumatology. The preset penetrates from a minimum depth of 1cm to a maximum of 12cm, and automatically translates from linear to trapezoidal format (4cm), and then to curvilinear (8cm). As a result, the Musculoskeletal preset can support inspection/injection of the peripheral joints as well as support the depth of penetration necessary for hip joint, and even epidurals.

Nerve
Read more +

The Nerve preset has been developed in collaboration with regional and peri-operative anaesthesiologists. It is a high-frequency linear imaging format optimised for interrogation of the peripheral nerves, to a depth of 5cm. It has been developed to show contrast between the nerve bundle, distinct from surrounding structures and yet maintain the detail resolution required to demonstrate the typical “honeycomb” appearance of individual nerve fascicles.

OB 1/GYN
Read more +

The OB 1/GYN preset is a dedicated curvilinear obstetric preset for in-utero assessment of pregnancy and gynaecological patients to a depth of 25cm. The preset has been optimised for first trimester pregnancy studies and is particularly popular in Labour & Delivery, obstetric, and resource-limited settings.

OB 2/3
Read more +

The OB 2/3 preset is a dedicated curvilinear obstetric preset for in-utero assessment of pregnancy and gynaecological patients to a depth of 25cm. The preset has been optimised for second and third trimester pregnancy studies and is particularly popular in Labour & Delivery, obstetric, and resource-limited settings.

Ophthalmic
Read more +

The Ophthalmic preset has been carefully developed with the appropriate MI operating scope for point-of-care ultrasound examinations of the eye. This typically involves looking at structural integrity of the orbit, foreign bodies as well as optic nerve sheath diameter (ONSD). It is a linear preset, depth range to 5cm.

Pediatric Abdomen
Read more +

The Paediatric Abdomen preset uses harmonic frequencies in a curvilinear format to support the clinical assessment of the size and morphology of abdominal organs, such as the liver and kidney. This preset uses a higher frequency and can penetrate as deep as 15cm, optimised for paediatric assessment.

Pediatric Cardiac
Read more +

The Paediatric Cardiac preset operates with a high-frame-rate phased array, and uses frequencies to allow reliable real-time echocardiographic interrogation of cardiac anatomy. This preset penetrates to 15cm and is optimised for pediatric patients, including higher frequencies than its adult-companion preset.

Pediatric Lung
Read more +

The Paediatric Lung preset has been optimised for demonstration of the pleural surface and lung sliding in the foreground, as well as A-line and B-lines throughout the 7cm field. It is a preset popular for the detection of pulmonary consolidation associated with paediatric pneumonia, and is one of the highest-used presets by our Global Health NGO partners.

Small Organ
Read more +

The Small Organ preset has been optimised for the investigation of small soft tissue structures such as the thyroid, parotid gland, lymph nodes and testes in a linear format to a depth of 6cm. It can be used for both the qualitative and quantitative assessment of organ size, morphology and vascularity. Examples of the latter include: assessment of testicular torsion as well as Hashimoto’s Thyroiditis.

Vascular: Access
Read more +

The Vascular: Access preset has been designed to meet the high-contrast, high-resolution demands of ultrasound-guided venipunctures and arterial access procedures, with a linear format. It optimises imaging from a minimum of 1cm through to 5cm, and has a low grey-scale appearance to “pop out” both the vasculature, as well as the needle/catheter path, and tip.

Vascular: Carotid
Read more +

The Vascular: Carotid preset has been designed to meet the high-contrast, high-resolution demands of assessment of the carotid arteries, for peripheral arterial disease. It has been designed to support the identification of plaque, hemodynamic disturbance and stroke screening. It optimises imaging to 6cm, to accommodate a range of patient types. The preset has been optimised with a relatively low grey-scale appearance to “pop out” intimal boundaries. A great video to help get you started can be found here.

Vascular: Deep Vein
Read more +

The Vascular: Deep Vein preset has been designed to meet the high-contrast, high-resolution demands of assessment of the peripheral deep veins. It has been designed to support the identification of thrombosis by supporting frame rates that accommodate the typical compression maneuvers, the contrast resolution to support the demonstration of the thrombus itself, as well as support to 8cm. The preset has been optimised with a relatively low grey-scale appearance to “pop out” intimal boundaries.

Cloud.

Storage
Unlimited
Data organization
Unlimited custom archives
User rights
Administrators, Regular Users (Unlimited)
Sharing
Anonymized image sharing (no user account required)

Security.

Data at rest
256-Bit AES
Data in transit
HTTPS TLS 1.2 Encryption
User security
Secure User Authentication, Passwords follow NIST Standards
Application deployment